BN-DS-T08 Lifting lugs for heat exchangers |
|
|
|
Design standard of Lifting lugs for heat exchangers. Use this standard for study purposes only. General Notes: - See equiment specification for any exceptions to this standard
- For material see equipment specification
- Provide channel, bonnet and shell cover with 2 lifting lugs
- The lifting lug locations shall be determined by the equipment supplier and shall be placed in the center of gravity of the lifted part
- Stresses in the lifting lugs shall be checked by vendor
| Weight in kg | A | B | | mm | mm | | < 30 | not required | | 30 - 250 | 12 | 65 | | 251 - 500 | 15 | 85 | | 501 - 1000 | 19 | 100 | | 1001- 1500 | 22 | 120 | | 1501 - 2500 | 25 | 150 | The next figure shows a typical design:
|