to home page

 
PCC Software

Software for creation of pipe classes and mechanical calculation of piping components. Read more ...
 
VES Software

Software for the design and mechanical calculation of pressure vessels and heat exchangers. Read more ...
Home Cost Codes Cost Code N-Account
Cost Code N-Account Print E-mail

N - Insulation

Project Account and Cost Code for Insulation


Stem sub Rest Detail Level UoM Description
N     1   Insulation
           
N*     2   Insulation Group
NA     2 M2 Equipment Insulation
NC     2 M Piping Insulation
NK     2 M2 Instrument Insulation
NY     2 M2 Misc. Insulation Items
           
NA *   3   Insulation Function
NA C   3 M2 Cold
NA H   3 M2 Hot
NA N   3 M2 Noise
NA P   3 M2 Personal Protection
           
NA _*   4   Insulation Material
NA _1   4 M2 Mineral Wool
NA _2   4 M2 Calcium Silicate
NA _3   4 M2 Foamglass
NA _4   4 M2 Polyurethane Foam
NA _5   4 M2 Polystyrene
NA _6   4 M2 Cork
           
NA ___*   5   Equipment Type
NA ___A   5 M2 Towers
NA ___F   5 M2 Storage Tanks
NA ___H   5 M2 Heaters
NA ___M   5 M2 Vessels
NA ___P   5 M2 Pumps
NA ___T   5 M2 Exchangers
           
NA __*   6   Insulation Shape
NA __1   6 M2 Shell
NA __2   6 M2 Head
NA __3   6 M2 Roof
NA __4   6 M2 Flat
           
NA   ___*** 7   Insulation Thickness (mm)
NA   ___... 7 M2 - any number -
           
NA ____*   8   Sheeting Material
NA ____1   8 M2 Aluminium
NA ____2   8 M2 Stainless Steel
NA ____3   8 M2 Aluminized Steel
NA ____4   8 M2 Galvanized Steel
NA ____5   8 M2 Polyethylene
NC *   3   Insulation Function
NC C   3 M Cold
NC H   3 M Hot
NC N   3 M Noise
NC P   3 M Personal Protection
           
NC _*   4   Insulation Material
NC _1   4 M Mineral Wool
NC _2   4 M Calcium Silicate
NC _3   4 M Foamglass
NC _4   4 M Polyurethane Foam
NC _5   4 M Polystyrene
NC _6   4 M Cork

Stem sub Rest Detail Level UoM Description
           
NC __*   5   Piping Catagory
NC __1   5 M Non-Traced
NC __2   5 M Steam/Hot Wtr.Traced
NC __3   5 M Electrical Traced
NC __4   5 M Jacketed
NC __5   5 M Tracing supply/Return Lines
NC __6   5 M Bundled Lines
           
NC ___*   6   Piping Component
NC ___B   6 M Fittings
NC ___F   6 M Flanges
NC ___M   6 M Manifolds
NC ___P   6 M Pipe
NC ___V   6 M Valves
NC ___X   6 M Piping
           
NC   * 7   Size Group
NC   ** 8   Size
           
NC   1 7   < 2"
NC   10 8   Small Bore
NC   11 8   1/8"
NC   12 8   0.25"
NC   13 8   3/8"
NC   14 8   0.5"
NC   15 8   5/8"
NC   16 8   0.75"
NC   17 8   1"
NC   18 8   1.25"
NC   19 8   1.5"
           
NC   2 7   2- 6"
NC   20 8   Medium Bore
NC   21 8   2"
NC   22 8   2.5"
NC   23 8   3"
NC   24 8   4"
NC   25 8   5"
NC   26 8   6"
           
NC   3 7   8-12"
NC   30 8   Large Bore
NC   31 8   8"
NC   32 8   10"
NC   33 8   12"
           
NC   4 7   14-24"
NC   40 8   LB4
NC   41 8   14"
NC   42 8   16"
NC   43 8   18"
NC   44 8   20"
NC   45 8   22"
NC   46 8   24"
           
NC   5 7   26-36"
NC   50 8   LB5
NC   51 8   26"
NC   52 8   28"
NC   53 8   30"
NC   54 8   32"
NC   55 8   34"
NC   56 8   36"

Stem sub Rest Detail Level UoM Description
           
NC   6 7   38-48"
NC   60 8   LB6
NC   61 8   38"
NC   62 8   40"
NC   63 8   42"
NC   64 8   44"
NC   65 8   46"
NC   66 8   48"
           
NC   7 7   >48"
NC   70 8   LB7
NC   71 8   52"
NC   72 8   54"
NC   73 8   56"
NC   74 8   58"
NC   75 8   60"
NC   76 8   64"
NC   77 8   68"
           
NC   ___*** 9   Insulation Thickness (mm)
NC   ___... 9 M2 - any number -
           
NC ____*   10   Sheeting Material
NC ____1   10 M Aluminium
NC ____2   10 M Stainless Steel
NC ____3   10 M Aluminized Steel
NC ____4   10 M Galvanized Steel
NC ____5   10 M Polyethylene
           
NK *   3   Insulation Function
NK C   3 M2 Cold
NK H   3 M2 Hot
NK N   3 M2 Noise
NK P   3 M2 Personal Protection
           
NK _*   4   Insulation Material
NK _1   4 M2 Mineral Wool
NK _2   4 M2 Calcium Silicate
NK _3   4 M2 Foamglass
NK _4   4 M2 Polyurethane Foam
NK _5   4 M2 Polystyrene
NK _6   4 M2 Cork
           
NK __*   5   Instrumentation Component
NK __1   5 M2 Housings
NK __2   5 M Leadlines
           
NK   ** 6   Line Size
           
NK   ___*** 7   Insulation Thickness (mm)
NK   ___... 7 M2 - any number -
           
NK ____*   8   Sheeting Material
NK ____1   8 M2 Aluminium
NK ____2   8 M2 Stainless Steel
NK ____3   8 M2 Aluminized Steel
NK ____4   8 M2 Galvanized Steel
NK ____5   8 M2 Polyethylene
 
 
Badger15_jpg.jpg
'reliability is yet to become the most important characterstic of modern companies'
home | privacy | legal