to home page

 
PCC Software

Software for creation of pipe classes and mechanical calculation of piping components. Read more ...
 
VES Software

Software for the design and mechanical calculation of pressure vessels and heat exchangers. Read more ...
Home Cost Codes Cost Code B-Account
Cost Code B-Account Print E-mail

B - Buildings

Project Account and Cost Code for Buildings


Stem sub Rest Detail Level UoM Description
B     1 M3 Buildings
           
B*     2   Building Group
BA     2 M3 Administration Buildings
BE     2 M3 Electrical Buildings
BF     2 M3 Service Buildings
BG     2 M3 Process Buildings
BK     2 M3 Control System Buildings
BM     2 M3 Maintenance Buildings
BP     2 M3 Pump & Compressor Houses
BS     2 M3 Storage Buildings & Warehouses
           
B*     3   Building Type
BA A   3 M3 Office Buildings
BA B   3 M3 Laboratory Buildings
BA C   3 M3 Change Houses
BA D   3 M3 General Purpose Buildings
           
BE A   3 M3 Main Stations
BE B   3 M3 Substations
BE C   3 M3 Emergency Generator Buildings
           
BF A   3 M3 Fire Stations
BF B   3 M3 Garages
BF C   3 M3 Truck Loading Offices
BF D   3 M3 Weigh Houses
BF E   3 M3 Guard Houses
           
BG A   3 M3 Process Buildings
           
BK A   3 M3 Control Building
BK B   3 M3 Analyser House
BK C   3 M3 Satellite House
           
BM A   3 M3 Maintenance Buildings
           
BP A   3 M3 Compressor Sheds
BP B   3 M3 Firewater Pump Houses
BP C   3 M3 Pump Houses
BP D   3 M3 Boiler Houses
           
BS A   3 M3 Storage Buildings
BS B   3 M3 Warehouses
           
B   ** 4   Building Number
B   .. 4 M3 - any code -
           
B _*   5   Building Component
B _**   6   Component Part
           
B _1   5 M3 Frame, Elevated Floors & Roof
B _11   6 M3 Frame
B _12   6 M2 Elevated Floors
B _13   6 M2 Roof
           
B _2   5 M2 Ext. Walls, Sidings, Windows & Doors
B _21   6 M2 External Walls
B _22   6 M2 External Sidings
B _23   6 M2 External Windows & Doors
           
B _3   5 M2 Int. Walls, Sidings, Windows & Doors
B _31   6 M2 Internal Walls
B _32   6 M2 Partitions
B _33   6 M2 Internal Windows & Doors

Stem sub Rest Detail Level UoM Description
B _4   5 LOT Finishing & Painting
B _41   6 M2 Finishing Ceiling
B _42   6 M2 Finishing Floors
B _43   6 M2 Finishing Walls
           
B _5   5 LOT Plumbing, Sanitary & Sewerage
B _51   6 LOT Roof Drainage
B _52   6 LOT Sanitary
B _53   6 LOT Plumbing
B _54   6 LOT Sewerage
           
B _6   5 M2 Lighting & Wiring
B _61   6 PC Fixtures
B _62   6 LOT Wiring
           
B _7   5 M3 Heating & Ventilation Systems
B _71   6 M3 Heating
B _72   6 M3 Ventilation
B _73   6 M3 Airconditioning
B _74   6 M3 Pressurizing
B _75   6 M3 Combined HVAC
           
B _8   5 PC Special Building Equipment
B _81   6 PC Elevators
B _82   6 PC Hoisting Facilities
B _83   6 PC Fire Fighting Equipment/Systems
B _84   6 PC Telephone Systems
B _85   6 PC Entrance Control Systems
           
B _9   5 PC Fixed Furniture
B _91   6 PC Laboratory Furniture
B _92   6 PC Change Room Furniture
           
B _***   7   Component Details 1
B _****   8   Component Details 2
           
B _1   5 M3 Frame, Elevated Floors & Roof
           
B _11   6 M3 Frame
           
B _11A   7 KG Steel Straight Profiles
B _11AA   8 KG Weight < 22 kg/m
B _11AB   8 KG Weight 22- 70 kg/m
B _11AC   8 KG Weight 70-120 kg/m
B _11AD   8 KG Weight >120 kg/m
           
B _11C   7 KG Special Girders
B _11CA   8 KG Welded Plate
B _11CB   8 KG Lattice Type
           
B _111   7 M3 Concrete Work
B _1111   8 M3 Concrete
B _1113   8 M2 Formwork
B _1114   8 KG Bolts
B _1115   8 KG Inserts
           
B _112   7 KG Rebar
B _1121   8 KG Mild Steel Bars
B _1122   8 KG High Tensile Steel Bars
B _1123   8 KG Wire Meshes
           
B _113   7 M3 Prefabricated Elements
B _1131   8 M3 Portals
B _1132   8 M3 Beams
B _1133   8 M3 Slabs

Stem sub Rest Detail Level UoM Description
B _12   6 M2 Elevated Floors
           
B _12B   7 M2 Steel Flooring
B _12BA   8 M2 Galvanized Grating
B _12BB   8 M2 Raised Pattern Plates
           
B _12D   7 KG Complete Steel Stairs
           
B _121   7 M3 Concrete Work
B _1211   8 M3 Concrete
B _1213   8 M2 Formwork
B _1214   8 KG Bolts
B _1215   8 KG Inserts
           
B _122   7 KG Reinforcing
B _1221   8 KG Mild Steel Bars
B _1222   8 KG High Tensile Steel Bars
B _1223   8 KG Wire Meshes
           
B _123   7 M3 Prefabricated Elements
B _1231   8 M3 Portals
B _1232   8 M3 Beams
B _1233   8 M3 Slabs
B _1234   8 M3 Stairs
           
B _13   6 M2 Roof
           
B _131   7 M3 Concrete Work
B _1311   8 M3 Concrete
B _1313   8 M2 Formwork
B _1314   8 KG Bolts
B _1315   8 KG Inserts
           
B _132   7 KG Reinforcing
B _1321   8 KG Mild Steel Bars
B _1322   8 KG High Tensile Steel Bars
B _1323   8 KG Wire Meshes
           
B _133   7 M3 Prefabricated Elements
B _1331   8 M3 Portals
B _1332   8 M3 Beams
B _1333   8 M3 Slabs
           
B _134   7 M2 Plate Material
B _1341   8 M2 Corrugated Galv. Steel
B _1342   8 M2 Corrugated Asbestos
B _1343   8 M2 Corrugated Polyester
B _1344   8 M2 Boxrib
B _1345   8 M2 Sandwich Panels
B _1346   8 M2 Aluminium Panels
           
B _135   7 M2 Roof Finishing
B _1351   8 M2 Insulation
B _1352   8 M2 Weatherproofing
B _1353   8 M Roofedge
B _1354   8 M Flashing
B _1355   8 PC Light-in Domes
B _1356   8 PC Ridge Vents

Stem sub Rest Detail Level UoM Description
B _2   5 M2 Ext. Walls, Sidings, Windows & Doors
           
B _21   6 M2 External Walls
           
B _211   7 M3 Concrete Work
B _2111   8 M3 Concrete
B _2113   8 M2 Formwork
B _2114   8 KG Bolts
B _2115   8 KG Inserts
           
B _212   7 KG Reinforcing
B _2121   8 KG Mild Steel Bars
B _2122   8 KG High Tensile Steel Bars
B _2123   8 KG Wire Meshes
           
B _216   7 M2 Masonry
B _2161   8 M2 Bricks
B _2162   8 M2 Concrete Blocks
B _2163   8 M2 Light Weight Blocks
B _216 ___... 10 M2 Size 0&& cm
           
B _22   6 M2 External Sidings
           
B _223   7 M3 Prefabricated Elements
B _2236   8 M2 Wall Plates
           
B _224   7 M2 Plate Material
B _2241   8 M2 Corrugated Galv. Steel
B _2242   8 M2 Corrugated Asbestos
B _2243   8 M2 Corrugated Polyester
B _2244   8 M2 Coated Steel,Boxrib
B _2245   8 M2 Sandwich
           
B _23   6 M2 External Windows & Doors
           
B _23A   7 M2 Single Doors
B _23A1   8 M2 Steel
B _23A2   8 M2 Wood
B _23A3   8 M2 Aluminium
           
B _23B   7 M2 Double Doors
B _23B1   8 M2 Steel
B _23B2   8 M2 Wood
B _23B3   8 M2 Aluminium
           
B _23C   7 M2 Overhead Doors
B _23C1   8 M2 Steel
B _23C2   8 M2 Wood
B _23C3   8 M2 Aluminium
           
B _23D   7 M2 Revolving Doors
B _23D1   8 M2 Steel
B _23D2   8 M2 Wood
B _23D3   8 M2 Aluminium
           
B _23E   7 M2 Sliding Doors
B _23E1   8 M2 Steel
B _23E2   8 M2 Wood
B _23E3   8 M2 Aluminium
           
B _23W   7 M2 Windows
B _23WS   8 M2 Safety Glass
B _23WD   8 M2 Double Layer Glass

Stem sub Rest Detail Level UoM Description
B _3   5 M2 Int. Walls, Sidings, Windows & Doors
           
B _31   6 M2 Internal Walls
           
B _316   7 M2 Masonry
B _3161   8 M2 Bricks
B _3162   8 M2 Concrete Blocks
B _3163   8 M2 Light Concrete Blocks
B _316 ___... 9 M2 Size 0&& cm
           
B _32   6 M2 Partitions
           
B _324   7 M2 Plate Material
B _3244   8 M2 Coated Steel,Boxrib
B _3245   8 M2 Sandwich
           
B _33   6 M2 Internal Windows & Doors
           
B _33A   7 M2 Single Doors
B _33A1   8 M2 Steel
B _33A2   8 M2 Wood
B _33A3   8 M2 Aluminium
           
B _33B   7 M2 Double Doors
B _33B1   8 M2 Steel
B _33B2   8 M2 Wood
B _33B3   8 M2 Aluminium
           
B _33W   7 M2 Windows
B _33WS   8 M2 Safety Glass
B _33WD   8 M2 Double Layer Glass
           
B _4   5 LOT Finishing & Painting
           
B _41   6 M2 Finishing Ceiling
           
B _411   7 M2 Plaster
B _412   7 M2 False Ceiling
B _416   7 M2 Paint
           
B _42   6 M2 Finishing Floors
           
B _423   7 M2 Cement Hardening
B _424   7 M2 Tiles
B _426   7 M2 Coating
           
B _43   6 M2 Finishing Walls
           
B _431   7 M2 Plaster
B _434   7 M2 Tiles
B _435   7 M2 Skinplate
B _436   7 M2 Coating
           
B _5   5 LOT Plumbing, Sanitary & Sewerage
           
B _51   6 LOT Roof Drainage
           
B _511   7 M Gutter
B _5111   8 M PVC
B _5112   8 M Zinc
B _5113   8 M Steel
           
B _512   7 PC Gravel Boxes

Stem sub Rest Detail Level UoM Description
B _513   7 M Down Spouts
B _5131   8 M PVC
B _5132   8 M Zinc
B _5133   8 M Cast Iron
B _5134   8 M CS-Galvanized
B _513 ___... 9 M Size 0&& inch
           
B _514   7 PC Collection Boxes
           
B _515   7 M Sewer Pipe
B _5151   8 M PVC
B _5152   8 M Cast Iron
B _5153   8 M Carbon Steel
B _5154   8 M Virtrified Clay
B _515 ___... 9 M Size 0&& inch
           
B _52   6 LOT Sanitary
           
B _521   7 PC Sinks & Washbasins
B _5211   8 PC Single Sink
B _5212   8 PC Double Sink
B _5213   8 PC Single Washbasin
B _5214   8 PC Multi. Washbasin
B _5215   8 PC Drinking Fountain
           
B _522   7 PC Toilet Facilities
B _5221   8 PC WC-Unit Floor Mounted
B _5222   8 PC WC-Unit Wall Mounted
B _5223   8 PC Urinal Floor Mounted
B _5224   8 PC Urinal Wall Mounted
           
B _523   7 PC Showers
B _5231   8 PC Normal
B _5232   8 PC Safety
B _5233   8 PC Eyewash
           
B _524   7 PC Water Heater
B _5241   8 PC Boiler Electrical
B _5242   8 PC Boiler Gas
           
B _53   6 LOT Plumbing
           
B _531   7 KG Water Piping
B _5311   8 KG Pipe
B _5312   8 KG Fittings
B _5313   8 KG Valves
B _531 ___... 9 KG Size 0&& inch
           
B _54   6 LOT Sewerage
           
B _541   7 PC Floor Drains
B _5411   8 PC C.I.
B _5412   8 PC PVC
           
B _542   7 M Sewer Piping
B _5421   8 M PVC
B _5422   8 M C.I.
B _5423   8 M Virtified Clay
B _542 ___... 9 M Size 0&& inch
           
B _543   7 M Septic Tank
B _5431   8 M Concrete Prefab
B _543 ___... 9 M Size 0&& m3

Stem sub Rest Detail Level UoM Description
B _6   5 M2 Lighting & Wiring
           
B _61   6 PC Fixtures
           
B _611   7 PC Lighting Fixtures
B _6111   8 PC Office Type
B _6112   8 PC Factory Type
B _6113   8 PC Water Proof
B _6114   8 PC Explosion Proof
           
B _612   7 PC Switches Etc.
           
B _62   6 LOT Wiring
           
B _621   7 PC Cables
           
B _622   7 PC Conduits
           
B _623   7 PC Ducting Systems
           
B _7   5 M3 Heating & Ventilation Systems
           
B _71   6 M3 Heating
           
B _711   7 M3 Hot Water Circulation
B _7111   8 PC Boiler
B _7112   8 PC Heating Panels
B _7113   8 KG Distr. Piping
B _7114   8 KG Fuel Supply Line
           
B _712   7 M3 Steam Circulation
B _7121   8 PC Boiler
B _7122   8 PC Heating Panels
B _7123   8 KG Distribution Piping
B _7124   8 KG Fuel Supply Line
           
B _713   7 M3 Electric Heating
B _7132   8 PC Heating Panels
           
B _72   6 M3 Ventilation
           
B _721   7 M3 Forced Draft
B _7211   8 PC Inlet Air Stack
B _7212   8 M2 Inlet Air Ducting
B _7213   8 PC Fan Sets
B _7214   8 M2 Distribution Ducting
B _7215   8 M2 Louvres
B _7216   8 M2 Filters
           
B _722   7 M3 Natural Draft
           
B _723   7 M3 Recirculation System
           
B _73   6 M3 Airconditioning
           
B _724   7 M3 Pressurizing
           
B _731   7 M3 Heating
B _7311   8 M3 Heating Elements
B _7312   8 M3 Tubing
           
B _732   7 M3 Cooling
B _7321   8 M3 Element
B _7322   8 M3 Tubing

Stem sub Rest Detail Level UoM Description
B _733   7 M3 Humidification System
           
B _734   7 M3 Combined System
B _7341   8 PC Multizone Airhandling Unit
B _7342   8 PC Fan Coil Unit
B _7343   8 PC Pumps
B _7344   8 PC Fan Sets
B _7345   8 M2 Ducting
B _7346   8 PC Dampers
B _7347   8 PC Diffusers
B _7348   8 PC Filters
           
B _8   5 PC Special Building Equipment
           
B _81   6 PC Elevators
           
B _811   7 PC Passenger Elevator excl. Cage
B _811..   8 PC Number of Stops 0&
B _811 ___... 9 PC Lift Capacity 0&& kg
           
B _812   7 PC Passenger Elevator incl. Cage
B _812..   8 PC Number of Stops 0&
B _812 ___... 9 PC Lift Capacity 0&& kg
           
B _813   7 PC Goods Elevator excl. Cage
B _813..   8 PC Number of Stops 0&
B _813 ___... 9 PC Lift Capacity 0&& kg
           
B _814   7 PC Goods Elevator incl. Cage
B _814..   8 PC Number ofStops 0&
B _814 ___... 9 PC Lift Capacity 0&& kg
           
B _82   6 PC Hoisting Facilities
           
B _821   7 PC Crane Manual Operated
B _8211   8 PC Hoist
B _8212   8 PC Trolley
B _8213   8 PC Crab(Travelling Beam)
           
B _822   7 PC Crane Electric Operated
B _8221   8 PC Hoist
B _8222   8 PC Trolley
B _8223   8 PC Crab(Travelling Beam)
           
B _82 ___... 9 PC Lifting Capacity 0&& tonne
           
B _83   6 PC Fire Fighting Equipment/Systems
           
B _831   7 PC Sprinkler Systems
B _832   7 PC Halon Systems
B _833   7 PC Firefighting Equipment
           
B _9   5 PC Fixed Furniture
           
B _91   6 PC Laboratory Furniture
           
B _911   7 PC Lab Benches
B _912   7 PC Fume Hoods
           
B _92   6 PC Change Room Furniture
           
B _921   7 PC Lockers
 
 